Freelander Service Procedures
HEATING AND VENTILATION
REPAIRS
80-3
Servo - air recirculation
$% 80.10.18
Remove
1. Remove glove box.
2. Disconnect multiplug from servo.
3. Remove screw securing servo to evaporator
and remove servo.
Refit
1. Fit servo to evaporator and secure with screw.
2. Connect multiplug to servo.
3. Fit glove box.
Switch - recirculation control
$% 80.10.21
Remove
1. Remove 3 heater control knobs.
2. Remove 2 screws securing heater control
finisher to heater controls and remove finisher.
3. Release switch and disconnect multiplug.
4. Remove switch.
Refit
1. Fit recirculation switch to heater control panel
and connect multiplug.
2. Fit heater control finisher to heater controls and
secure with screws.
3. Fit heater control knobs.