Workshop Manuals Factory service & repair Nissan and Datsun
01 QUICK REFERENCE INDEX02 Front Cover03 Foreword04 Table of Contents05 General Information06 Windshield Header Trim07 Windshield Header Molding08 Weatherstrips and Retainers09 Rear Seat10 Quarter Trim Panel11 Quarter Window and Regulator12 Door and Door Window13 Seat Belts14 Back and Quarter Belt Moldings15 Headliner Assembly16 Top Cover Assembly17 Backlite Assembly18 Stay Pads, Side and Rear19 No. 1 Bow20 No. 2 Bow21 No. 3 Bow22 No. 4 Bow23 Rear and Side Rail24 Hydraulic System25 Electrical26 Deck Lid Hinge and Trunk Trim27 Body Structural28 Index29 Back Cover30 QUICK REFERENCE CHART
Nissan and Datsun Nissan 240SX 1991-92 Workshop Manual01 · QUICK REFERENCE INDEX
01 · General

DESCRIPTION — Refrigeration System - Nissan 240SX 1991-1992 Workshop Manual

Make
Nissan and Datsun
Model
240SX Nissan 240SX 1991-92 Workshop Manual
Section
General › DESCRIPTION — Refrigeration System - Nissan 240SX 1991-1992 Workshop Manual
QUICK REFERENCE INDEXDESCRIPTION — Refrigeration System - Nissan 240SX 1991-1992 Workshop Manual

DESCRIPTION — Refrigeration System

DESCRIPTION — Refrigeration System

Refrigeration Cycle

REFRIGERANT FLOW

The refrigerant flows in the standard pattern, that is, through the compressor, the condenser, the liquid tank, through the evaporator, and the compressor. The refrigerant evaporation through the evaporator coil is controlled by an externally equalized expan- sion valve, located inside evaporator case.

FREEZE PROTECTION

Under normal operating conditions, when the A/C is switched on, the compressor runs continuously, and the evaporator pressure, and therefore temperature, is controlled by the V-5 variable displacement compressor. If evaporator coil temperature falls below a specified point, the thermo-control amplifier interrupts com- pressor operation. When evaporator coil temperature rises above the specification, compressor opera- tion will resume. This condition (compressor cycling) indicates a malfunction in the system.

REFRIGERANT SYSTEM PROTECTION

Dual-pressure switch The refrigerant system is protected against excessively high or low pressure by the dual-pressure switch, located on the liquid tank. If the system pressure rises above, or falls below the specifications, the dual-pressure switch opens to interrupt compressor operation. Fusible plug Open at temperatures above 105°C (221°F), thereby discharging refrigerant to the atmosphere. If this plug is melted and opened, check the refrigerant line and replace the liquid tank. Pressure relief valve The refrigerant system is also protected by a pressure relief valve, located on the end of compressor. When the pressure of the refrigerant in the system increases to an abnormal level [more than 3,727 kPa (38 kg/cm?, 540 psi)], the release port on the pressure relief valve automatically opens and releases refrigerant into the atmosphere. t; Pressure relief High-pressure Low-pressure valve Lan gas liquid

| Compressor

cay High-pressure

|, Low-pressure

| ee liquid gas 4 T ie iv Outside air u i VVVWV ) Condenser |

Blower motor

Expansion valve Fusible plug Dual-pressure switch SHA459D

HA-10

Parts & tools for this job For Nissan 240SX

As an Amazon Associate we earn from qualifying purchases.