Workshop Manuals Factory service & repair Nissan and Datsun
01 QUICK REFERENCE INDEX02 Front Cover03 Foreword04 Table of Contents05 General Information06 Windshield Header Trim07 Windshield Header Molding08 Weatherstrips and Retainers09 Rear Seat10 Quarter Trim Panel11 Quarter Window and Regulator12 Door and Door Window13 Seat Belts14 Back and Quarter Belt Moldings15 Headliner Assembly16 Top Cover Assembly17 Backlite Assembly18 Stay Pads, Side and Rear19 No. 1 Bow20 No. 2 Bow21 No. 3 Bow22 No. 4 Bow23 Rear and Side Rail24 Hydraulic System25 Electrical26 Deck Lid Hinge and Trunk Trim27 Body Structural28 Index29 Back Cover30 QUICK REFERENCE CHART
Nissan and Datsun Nissan 240SX 1991-92 Workshop Manual01 · QUICK REFERENCE INDEX
01 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

Make
Nissan and Datsun
Model
240SX Nissan 240SX 1991-92 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
QUICK REFERENCE INDEXDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

Discharging Compressor

Low pressure

High pressure Ll —_——e \ gauge

WARNING: ~ gauge \ From _ Discharge only into your recycling equipment. evaporator To condenser Do not release refrigerant into the air. Slowly open the valves to discharge the refrigerant. If they are opened quickly, compressor oil will also be discharged. High pressure valve Refrigerant Vacuum pump valve recycling equipment SHA734C Evacuation Compressor Low pressure High pressure gauge gauge

EVACUATION PROCEDURE

From evaporator | ——

1. Completely tighten the low pressure and high pressure To condenser adapter valves. Refrigerant container Turn on the high and low pressure service valves. Low pressure valve , Open the high and low pressure valves and vacuum pump af (close) =

\ High pressure valve

valve of the manifold gauge set. (open) Run the vacuum pump. Vacuum Vacuum pump valve Charging cylinder pump SHA735C Perform evacuation for more than five minutes to stabilize the vacuum inside the system. Check to ensure that the low pressure gauge indicates —98.6 to —101.3 kPa (—740 to —760 mmHg, —29.13 to —29.92 inHg). Shut off the high and low pressure valves and vacuum -101.3 kPa pump valve of the manifold gauge set. (-760 mmHg, '-29.92 inHg)

—_— cS = RHA597B

CHECKING AIRTIGHTNESS

High pressure Low pressure ae gauge

1. Shut off the high and low pressure valves and vacuum gauge pump valve of the manifold gauge set, and leave the system as it is for 5 to 10 minutes. |

is| return

lowed. Make sure that the needle of the low pressure gauge will not move back toward the atmospheric pressure side (gauge pressure 0). If any reverse movement is noted, it indicates poor system “a7 cH airtightness. Service the system until airtightness is complete. TOK If pressure changes approx. 13.3 kPa (100 mmHg, 3.94 inHg) in 10 minutes, the refrigerant in the system will be exhausted in about one month. Low pressure valve cock [LO] (close) To high To low To pressure vacuum pressure service service pump valve valve High pressure Vacuum pump valve valve cock cock (close) [Ht] (close)

RHAS98B HA-29

Parts & tools for this job For Nissan 240SX