Workshop Manuals Factory service & repair Nissan and Datsun
01 QUICK REFERENCE INDEX02 Front Cover03 Foreword04 Table of Contents05 General Information06 Windshield Header Trim07 Windshield Header Molding08 Weatherstrips and Retainers09 Rear Seat10 Quarter Trim Panel11 Quarter Window and Regulator12 Door and Door Window13 Seat Belts14 Back and Quarter Belt Moldings15 Headliner Assembly16 Top Cover Assembly17 Backlite Assembly18 Stay Pads, Side and Rear19 No. 1 Bow20 No. 2 Bow21 No. 3 Bow22 No. 4 Bow23 Rear and Side Rail24 Hydraulic System25 Electrical26 Deck Lid Hinge and Trunk Trim27 Body Structural28 Index29 Back Cover30 QUICK REFERENCE CHART
Nissan and Datsun Nissan 240SX 1991-92 Workshop Manual01 · QUICK REFERENCE INDEX
01 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

Make
Nissan and Datsun
Model
240SX Nissan 240SX 1991-92 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
QUICK REFERENCE INDEXDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

Charging Refrigerant (Cont'd)

CALCULATING CHARGING AMOUNT OF REFRIGERANT

1. Record the amount of refrigerant in the sight glass before charging.

2. Subtract the required amount of refrigerant (charge quan- tity specified for the vehicle) from the amount of refrigerant recorded in step 1. Charge refrigerant into the system until the remaining value equals to the value indicated on the Referigerant level sight glass. before charging Example: Level in sight glass: 3 Ib 8 oz Specified amount Charge specification (from S.D:S.) 2.0 - 2.4 Ib. of charge Calculate charge quantity into Ib and oz as follows: 1 Ib = 16 oz, Refr igerant level and 0.1 Ib = 1.6 oz, so that 2.0 Ib = 32 0z, 2.4 lb = 32 + (4x after charging

1.6) = 32 + 6.4 = 38.4, round off to 38. Therefore our charge quantity will be between 32 and 38 oz, or 2 Ib 0 oz to 2 Ib 6 oz. Subtract 2 Ib 6 oz from the level in the sight glass (3 Ib 8 oz) = 1 Ib 2 oz. This will be our ending point.

RHA681B lf a flow meter is not available, the amount of charged refriger- 2 3016 ant also can be determined by subtracting the weight of the canister measured after charging from its weight measured before charging.

0000

RHA602B

HA-32

Parts & tools for this job For Nissan 240SX

As an Amazon Associate we earn from qualifying purchases.