01 QUICK REFERENCE INDEX02 Front Cover03 Foreword04 Table of Contents05 General Information06 Windshield Header Trim07 Windshield Header Molding08 Weatherstrips and Retainers09 Rear Seat10 Quarter Trim Panel11 Quarter Window and Regulator12 Door and Door Window13 Seat Belts14 Back and Quarter Belt Moldings15 Headliner Assembly16 Top Cover Assembly17 Backlite Assembly18 Stay Pads, Side and Rear19 No. 1 Bow20 No. 2 Bow21 No. 3 Bow22 No. 4 Bow23 Rear and Side Rail24 Hydraulic System25 Electrical26 Deck Lid Hinge and Trunk Trim27 Body Structural28 Index29 Back Cover30 QUICK REFERENCE CHART
Nissan and Datsun Nissan 240SX 1991-92 Workshop Manual01 · QUICK REFERENCE INDEX
01 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

Make
Nissan and Datsun
Model
240SX Nissan 240SX 1991-92 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
QUICK REFERENCE INDEXDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

Charging Refrigerant (Cont'd)

If a flow meter is not available, the amount of charged refriger- ant also can be determined by subtracting the weight of the container measured after charging from its weight measured before charging.

Weight scale

RHA602B

PRELIMINARY CHARGING OF REFRIGERANT

Pr -Sight

1. Open outlet valve of charging cylinder. ann glass

2. Slowly open high pressure side valve of manifold gauge to charge refrigerant from the high pressure side. Lf 5 Lo

3. Close high pressure valve after charging approx. 200 g me > (7.05 oz) refrigerant.

CAUTION: The refrigerant in charging cylinder is kept in liquid state, so the refrigerant should be charged from high pressure side. Do LT ' not start engine with high pressure valve kept open. RHA682B

PRELIMINARY CHECK FOR REFRIGERANT LEAKS

1. Make sure that the gauge manifold valve is closed.

2. Check for refrigerant leak from each connector in the sys- tem using the leak detector. At this point, the pressure in the system is not high. Only large amounts of refrigerant leak due to loose pipe joints, etc. can be detected.

CHARGING REFRIGERANT

1. Slowly open high pressure valve of manifold gauge, and To pipe joint charge calculated amount of refrigerant in ““CALCULATING RHA601B

CHARGING AMOUNT OF REFRIGERANT”.

CAUTION: The refrigerant in charging cylinder is kept in liquid state, so the refrigerant should be charged from high pressure side. Do not start engine with high pressure valve kept open.

2. Close high pressure valve of manifold gauge.

3. Make sure that the calculated amount of refrigerant remains in sight glass.

4. Close charging cylinder outlet valve.

5. Turn off heater if it is on (when using heater equipped type).

Inspection for Refrigerant Leaks

WORK PROCEDURE

To facilitate inspection for refrigerant leaks, establish the fol- lowing conditions: e Start engine. Run air conditioner. Set blower fan control to MAX. Set temperature control to FULL COLD. Run the refrigerant system for more than 5 minutes after setting the above-mentioned conditions (to circulate refrig- erant through the system).