DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
- Make
- Nissan and Datsun
- Model
- 240SX Nissan 240SX 1991-92 Workshop Manual
- Section
- General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
DISCHARGING, EVACUATING, CHARGING AND CHECKING
DISCHARGING, EVACUATING, CHARGING AND CHECKING
Charging Refrigerant (Cont'd)
If a flow meter is not available, the amount of charged refriger- ant also can be determined by subtracting the weight of the container measured after charging from its weight measured before charging.
Weight scale
RHA602B
PRELIMINARY CHARGING OF REFRIGERANT
Pr -Sight
1. Open outlet valve of charging cylinder. ann glass
2. Slowly open high pressure side valve of manifold gauge to charge refrigerant from the high pressure side. Lf 5 Lo
3. Close high pressure valve after charging approx. 200 g me > (7.05 oz) refrigerant.
CAUTION: The refrigerant in charging cylinder is kept in liquid state, so the refrigerant should be charged from high pressure side. Do LT ' not start engine with high pressure valve kept open. RHA682B
PRELIMINARY CHECK FOR REFRIGERANT LEAKS
1. Make sure that the gauge manifold valve is closed.
2. Check for refrigerant leak from each connector in the sys- tem using the leak detector. At this point, the pressure in the system is not high. Only large amounts of refrigerant leak due to loose pipe joints, etc. can be detected.
CHARGING REFRIGERANT
1. Slowly open high pressure valve of manifold gauge, and To pipe joint charge calculated amount of refrigerant in ““CALCULATING RHA601B
CHARGING AMOUNT OF REFRIGERANT”.
CAUTION: The refrigerant in charging cylinder is kept in liquid state, so the refrigerant should be charged from high pressure side. Do not start engine with high pressure valve kept open.
2. Close high pressure valve of manifold gauge.
3. Make sure that the calculated amount of refrigerant remains in sight glass.
4. Close charging cylinder outlet valve.
5. Turn off heater if it is on (when using heater equipped type).
Inspection for Refrigerant Leaks
WORK PROCEDURE
To facilitate inspection for refrigerant leaks, establish the fol- lowing conditions: e Start engine. Run air conditioner. Set blower fan control to MAX. Set temperature control to FULL COLD. Run the refrigerant system for more than 5 minutes after setting the above-mentioned conditions (to circulate refrig- erant through the system).