Workshop Manuals Factory service & repair Nissan and Datsun
01 QUICK REFERENCE INDEX02 Front Cover03 Foreword04 Table of Contents05 General Information06 Windshield Header Trim07 Windshield Header Molding08 Weatherstrips and Retainers09 Rear Seat10 Quarter Trim Panel11 Quarter Window and Regulator12 Door and Door Window13 Seat Belts14 Back and Quarter Belt Moldings15 Headliner Assembly16 Top Cover Assembly17 Backlite Assembly18 Stay Pads, Side and Rear19 No. 1 Bow20 No. 2 Bow21 No. 3 Bow22 No. 4 Bow23 Rear and Side Rail24 Hydraulic System25 Electrical26 Deck Lid Hinge and Trunk Trim27 Body Structural28 Index29 Back Cover30 QUICK REFERENCE CHART
Nissan and Datsun Nissan 240SX 1991-92 Workshop Manual01 · QUICK REFERENCE INDEX
01 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

Make
Nissan and Datsun
Model
240SX Nissan 240SX 1991-92 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
QUICK REFERENCE INDEXDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

pischarging (Cont'd)

To drain A/C system oil accumulator, open ‘Accumulator Pressurizing’’ valve for approximately 15 seconds to allow Air purge NN |_— Oil drain valve some compressor discharge pressure back into accumula- valve { tor. Close ‘‘Accumulator Pressurizing’”’ valve and open “‘Oil rH Accumulator Drain’ valve slowly and drain accumulator. Do not allow pressurizing valve accumulator to completely depressurize. When oil stops an Tank draining, close ‘Oil Drain’ valve. Be sure to replace oil in Oil bottle / A/C system before servicing. Turn off ‘“‘Recovery”’ switch. ‘t When recovery tank is full, trip switch at the bottom of coON weight platform will de-energize compressor and ‘Tank SHA892C Full’ light will come on. Recycle refrigerant in tank before removing. Air purge line

Refrigerant tank

(Yellow hose)

REFRIGERANT RECYCLING

The recycling of reclaimed refrigerant is essential in order to assure that the refrigerant which meets the standards is re-used. For maximum efficiency, full tanks of recovered refrigerant should be recycled. As required, tanks containing a minimum of 3.6 kg (8 Ib) of refrigerant can be recycled. eo, Gas line Liquid line For greatest efficiency, recycling full tanks of refrigerant is rec-

(Blue hose) ~

(Red hose)

ommended. SHA891C

1. Make certain both valves on recovery tank are open.

2. Turn on ‘Recycling’ switch. Recycling solenoid will be energized. |

3. Depress start switch. Compressor will start, and ‘‘Recycling On’”’ light will come. Refrigerant will be seen going through Moisture moisture indicator at start up. The sightglass will not com- indicator pletely fill with refrigerant. ©

4. Allow the station to operate until moisture indicator turns green. If moisture indicator does not turn green after 40 minutes, remove and replace filter.

5. After recycling for approximately 5 minutes, check air purge indicator. If green pointer on air purge indicator SHA895C leads red pointer by more than 10 psi (2 small divisions), bleed tank through air purge valve on the back of unit until both pointers are equal. Repeat as necessary. Air purge indicator

RR Wo SHA896C Evacuation Compressor Low pressure

High pressure gauge

gauge \

EVACUATION PROCEDURE

From evaporator — To condenser

1. Connect vacuum hose to vacuum pump.

2. Open high and low pressure valves of manifold gauge set and additional valve.

3. Run vacuum pump. (open) Lt

\ High pressure valve

Additional (open) f Vacuum valve (open) | pump SHA952C HA-28