DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
- Make
- Nissan and Datsun
- Model
- 240SX Nissan 240SX 1991-92 Workshop Manual
- Section
- General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 240SX 1991-1992 Workshop Manual
DISCHARGING, EVACUATING, CHARGING AND CHECKING
DISCHARGING, EVACUATING, CHARGING AND CHECKING
pischarging (Cont'd)
To drain A/C system oil accumulator, open ‘Accumulator Pressurizing’’ valve for approximately 15 seconds to allow Air purge NN |_— Oil drain valve some compressor discharge pressure back into accumula- valve { tor. Close ‘‘Accumulator Pressurizing’”’ valve and open “‘Oil rH Accumulator Drain’ valve slowly and drain accumulator. Do not allow pressurizing valve accumulator to completely depressurize. When oil stops an Tank draining, close ‘Oil Drain’ valve. Be sure to replace oil in Oil bottle / A/C system before servicing. Turn off ‘“‘Recovery”’ switch. ‘t When recovery tank is full, trip switch at the bottom of coON weight platform will de-energize compressor and ‘Tank SHA892C Full’ light will come on. Recycle refrigerant in tank before removing. Air purge line
Refrigerant tank
(Yellow hose)
REFRIGERANT RECYCLING
The recycling of reclaimed refrigerant is essential in order to assure that the refrigerant which meets the standards is re-used. For maximum efficiency, full tanks of recovered refrigerant should be recycled. As required, tanks containing a minimum of 3.6 kg (8 Ib) of refrigerant can be recycled. eo, Gas line Liquid line For greatest efficiency, recycling full tanks of refrigerant is rec-
(Blue hose) ~
(Red hose)
ommended. SHA891C
1. Make certain both valves on recovery tank are open.
2. Turn on ‘Recycling’ switch. Recycling solenoid will be energized. |
3. Depress start switch. Compressor will start, and ‘‘Recycling On’”’ light will come. Refrigerant will be seen going through Moisture moisture indicator at start up. The sightglass will not com- indicator pletely fill with refrigerant. ©
4. Allow the station to operate until moisture indicator turns green. If moisture indicator does not turn green after 40 minutes, remove and replace filter.
5. After recycling for approximately 5 minutes, check air purge indicator. If green pointer on air purge indicator SHA895C leads red pointer by more than 10 psi (2 small divisions), bleed tank through air purge valve on the back of unit until both pointers are equal. Repeat as necessary. Air purge indicator
RR Wo SHA896C Evacuation Compressor Low pressure
High pressure gauge
gauge \
EVACUATION PROCEDURE
From evaporator — To condenser
1. Connect vacuum hose to vacuum pump.
2. Open high and low pressure valves of manifold gauge set and additional valve.
3. Run vacuum pump. (open) Lt
\ High pressure valve
Additional (open) f Vacuum valve (open) | pump SHA952C HA-28